1. Remove the rails attached to the faulty Storage Node and attach them to the replacement node.
a. Unscrew the two screws that attach the rails to the Storage Node.
Figure 3-51. Storage Node inner rail removal
b. Attach the rails to the replacement Storage Node.
2. Align the rails on the replacement Storage Node with the rack rails.
3. Push the Storage Node into the rack.
4. Tighten the thumb screws on the front of the Storage Node.
5. Replace the drives in the same order that they were removed in. For more information, refer to
Installing a 2.5 inch drive
6. Reconnect the cables in the back of the Storage Node in the original configuration listed in
cabling
on page 117.
7. Power on the Storage Node using the power button on the front panel.
8. If Western Digital Corporation support is not onsite, contact customer support for the final post-
replacement procedures for bringing the Storage Node online.

3.6 Storage Enclosure Basic part replacement instructions

The following sections provide information about Storage Enclosure Basic part replacement.

3.6.1 Replacing Storage Enclosure Basic I/O modules

Caution: Disconnect all power sources before servicing.
Table 3-31. I/O module replacement overview
Required Tools
None
Warning: The I/O module is bottom-heavy. Support the I/O module from the
bottom during replacement.

3.6.1.1 Removing a Storage Enclosure Basic I/O module

To remove a Storage Enclosure Basic I/O module:
on page 72.
Personnel
1
Replacement Time
3 min