b. Plug in the HD miniSAS cables into the HD miniSAS ports.
c. Plug in the power cords into the power cord ports at the bottom of each power supply unit.
d. Push the I/O module into the chassis until seated against the sleds.
e. Lock the I/O module handle by pushing the latch handle into the I/O module.
Figure 11-37. Locking the I/O module
13. Reconnect the enclosure power cords and network cables.
14. Verify that the fault LED is no longer on.
15. If the fault LED is still on, do the following:
a. Swap the sled that is indicating a fault with another enclosure sled.
b. If the fault LED is still lit, the sled may need to be replaced.
16. If the fault LED is not on, restart the Storage Node and verify that the Storage Enclosure Basic is
functioning properly.

11.1.6 Troubleshooting a drive fault LED

To troubleshoot the drive fault LED, do the following: