EN
J6
6.5
EXPANSION CONNECTOR
B EBA
RS485
RS 485
LINK BBU
7. DISPLAY
At power-on the display shows the board type "
and nally the status or error code.
The status (initial
) or error code is always displayed except in programming menu or when a blocking error is present.
The status code is shown on the rst 2 digits.
: Idle
: Opening
: Opening limit switch reached
: Stop activated during opening
: Closing
: Closing limit switch reached
: Stop activated during closing
A standard cycle, without errors, is always 2
On the third digit and dot, additional information is shown:
Display
STATUS
UPS active, mains voltage failure
STOP signal active
"Termon" active
Photocell engaged
Control unit
6.6
B EBA
TCP/IP
TCP/IP
MODULE
GATEWAY
", then the FW release X.Y.Z, then the type of bollard (see table on chapter cap. 5),
7.1 STATUS CODE
Hydraulic bollards only:
->
3 when opening, 5
- 28 -
J8
PROGRAMMER CONNECTOR
FOR RECEIVER
: Stop due to photocell triggering
: Opening after photocell triggering
: Pause after photocell triggering
: Stop due to a detected obstacle
: Opening after a detected obstacle
: Pause after obstacle detection
: Maximum working time in opening reached
: Maximum working time in closing reached
->
6 when closing