J3A/J3B Power Terminal Block; J4 Outputs/Accessories Terminal Block - BFT PERSEO-CBE Installation And User Manual

Table of Contents

Advertisement

EN
MOT A - COM - MOT B
Motor connection, MOT A for open direction and MOT B for close direction
CAP
Capacitor if not present on motor(s) side
EV1
Electrovalve (230Vac RAC), for hydraulic bollards only
EV2
Electrovalve (230Vac RAC), for ECD bollards equipped only
TRAFFIC LIGHT - GREEN LAMP
Tra c light outputs green lamp (230Vac)
TRAFFIC LIGHT - RED LAMP
Tra c light outputs red lamp (230Vac)
FLASHING LIGHT
Flashing light, (230Vac)
EF ELECTRIC BRAKE
Connection
Activation is possible only when the bollard is completely lifted (24Vcc starting / 12Vcc to stand on).
Power supply for accessories
24Vac, 1A max
24 Vac2
Cover lights 24Vac
Self-powered output. 24Vac, 800mA max
Cover lights 12Vac (XPASS B 1200C only)
Self-powered output. 12Vac, 800mA max
Cover buzzer 24Vac
Self-powered output. 24Vac, 100mA max
Cover buzzer 12Vac (XPASS B 1200C only)
Self-powered output. 12Vac, 100mA max
OUT4
OUT4/AUX
AUX
Programmable free contact relay output, max. 500mA 24 Vac/dc (parameter
OUT5/2ndRX
OUT5
2ndRX
Programmable free contact relay output/ N.O. output of the 2nd radio receiver channel; 500mA max, 24Vac/dc
(parameter
Control unit
J3A/J3B
6.2
J4
6.3
OUTPUTS/ACCESSORIES TERMINAL BLOCK
OUTPUT (Electomechanical bollards only)
for two white power supply cables for the motor's parking electric brake.
- level 2)
POWER TERMINAL BLOCK
- 26 -
- level 2)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents