3Rd Level Programming - BFT PERSEO-CBE Installation And User Manual

Table of Contents

Advertisement

EN
Deceleration torque (not avail-
able for hydraulic bollards)
Exiting the menu/saving
Description of level 2 parameters
·
: Request for maintenance
-
: the request for maintenance is not active.
-
: after the programmed cycles set by the counters
-
: after the programmed cycles set by the counters
the bollard lights ash twice.
-
·
: Programming maintenance cycles in thousands and millions
These two parameters set the number of cycles after which a request for maintenance is signalled.
Thousands of cycles can be set with the
after 275 000 cycles, set
·
: Closing limit switch presence.
This parameter must be set only for bollards with additional limit switch installed for closed-fully up position. After every default
operation it is set to
=
=
·
;
: Assistance required
If con gured, the contact indicates that the electronic control unit detected an error in the automation and in particular, the failure
of the travel stop or the solenoid valve (hydraulic bollards only). The error is also signalled by the triple ashing of the cover lights, if
installed
·
: TERMON (integrated electronic motor heating system)
Should be activated ONLY when the ambient temperature where the bollard is installed drops below a minimum of 0°C for all the
day.
=
, TERMON is disabled (default)
=
, minimum heating
=
, maximum heating
·
: Deceleration torque (electromechanical bollards only)
Sets the deceleration speed at the end of the closing manoeuvre.
The value of the deceleration speed at the end of opening is factory preset and cannot be modi ed.
The following table gives the 3rd level functions and the adjustable parameters.
= DEFAULT value set in factory.
Par.
Function
PDM dynamic input polarity
Limit switch connection
Pressure switch polarity (for
hydraulic bollards only)
ECD Pressure switch polarity
Input AUX polarity
Output 4 polarity
Output 5 polarity
Commands accepted during pause
time
Pressing the "F" key exits the programming menu and changes are saved
parameter, millions of cycles with the
to . and
to
.
for
and
bollards,
for the others.
8.4
3rd LEVEL
: input N.O.
: input N.C.
: series (N.O. 2-wire sensors)
: parallel (N.C. 3-wire sensors)
: N.O. (used until 2012)
: N.C. (used from 2013)
: N.O.
: N.C.
: N.O.
: N.C.
: N.O.
: N.C.
: OFF
: ON
Control unit
and
, the programmed output is activated (see parameters
and
, the programmed output is activated (see parameters
PROGRAMMING
= parameter value set during installation: should be lled if
DEFAULT value is modi ed.
Settable data
- 32 -
parameter. Example: to set maintenance alarm
,
)
,
) and

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents