4Th Level Programming - BFT PERSEO-CBE Installation And User Manual

Table of Contents

Advertisement

Programmable PDM input for spe-
cial functions
Radio channel 1 command selec-
tion
Select mains frequency
Exiting the menu/saving
Description of level 3 parameters
·
: Input polarity
For N.O. or N.C. input polarity con guration.
·
: Output 4 polarity, Output 5 polarity
Output polarity: The outputs can be con gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
·
: Output polarity
The outputs can be con gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
·
: Enable command during the pause time
Depending also upon other settings, the system accepts or not the commands from inputs.
·
: Special PDM functions
=
PDM is used as opening enable. As long as it is not active, no opening command is accepted. Also no close command is ac-
cepted so the bollard remains open.
=
The PDM functions as described in point 1, but in case of automatic logic, the pause time is reloaded.
=
The PDM function enables the TERMON system. Based on the setting of the
contact activates or deactivates the TERMON system. This allow the TERMON function to be controlled by a calendar and/or
a thermostat.
·
: Pressure switch polarity
N.O.: Pressure switch type used until 2012.
N.C.: Pressure switch type used from 2013 on.
The following table gives the 4th level functions and the adjustable parameters.
= DEFAULT value set in factory.
Par
Function
Communication protocol
U-LINK mode
U-LINK adress
Modbus/RTU ID
MODBUS RTU speed
Cycles counter
Historical errors
Control unit
: None
: Opening Enable when active
: Opening Enable and pause time reset (with
: TERMON Enabled when active
: Opening Enable and pause time reset (with
: Receiver channel 1 not used
: Receiver channel 1 mapped to START
: Receiver channel 1 mapped to OPEN (with
: Value of main frequency in Hertz (Hz)
Pressing the "F" key exits the programming menu and changes are saved
4TH
8.5
LEVEL PROGRAMMING
Settable data
: disabled
: U-LINK
: Modbus/RTU
: Slave
: Master
: For Slave
: For Master
. : 19 200 baud
. 38 400 baud
Read only parameter, in thousands (x1000)
: do not clear (keeps) the list
: clear the list
- 33 -
=
), when active
=
), when active
=
special function)
parameter, the closing or opening of the
= parameter value set during installation: should be lled if
DEFAULT value is modi ed.
EN
.