Troubleshooting and fault elimination
Troubleshooting
3.2.2

Working with the history buffer

Fault detection and reaction
Contains the fault detection for every memory location and the reaction to the fault.
– e.g. "OH3 TRIP"
– With a fieldbus, the faults are indicated by a fault number.
Please note:
For faults occuring at the same time with different reactions:
– Only the reaction of the fault with the higest priority (priority = TRIP
Warning) is entered into the memory.
For faults occuring at the same time and with the same reaction (e.g. 2 messages):
– Only the fault which occurred first is entered.
Time
Contains the times when the faults occurred
– e.g. "1234567 s"
– Reference time is the mains switch-on time (see dialog box Diagnosis 93xx , top right field)
Please note:
If a fault is immediately followed by another several times, only the time of the last occurrence
is stored.
Frequency
Contains the frequency of a fault immediately followed by the same fault. The time of the last
occurrence is stored.
Reset fault
Click TRIP reset to reset the fault
Delete history buffer
This function is possible only when no fault is active.
Click History buffer reset to delete the history buffer.