Save parameter set

The parameters must be saved so that the changed settings do not get lost after mains
disconnection.
You can establish up to four parameter sets, e.g. if you process different materials on a
machine or if this is required by different operating states (setup mode, "stand-by").
If you need only one parameter set, save the modifications permanently under parameter set
1, since the controller automatically loads parameter set 1 after mains connection.

How to proceed

1. Change from the menus to the code level using the arrow keys.
"Code" is displayed.
2. Select C0810/1 using
3. Change to the parameter level using PRG.
"Para" is displayed.
4. Select C0810/1 using
Note: If the parameter set is to be saved under another number, select 2, 3, or 4 instead of 1.
5. Press SHIFT + PRG.
"OK" is indicated for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3, 4).
Parameter setting using the keypad
or
C0003.
Y
B
or
parameter on 1 (also possible at travelling drive).
Y
B
Parameter setting