Reset Of Fault Messages - Lenze 9300 Series Operator's Manual

Hide thumbs Also See for 9300 Series:
Table of Contents

Advertisement

3.4
Reaction on
operating errors
TRIP/ FAIL-QSP
Message
Warning
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net
Troubleshooting and fault elimination

Reset of fault messages

Measures for re-commissioning
After the error has been eliminated, the drive can be restarted when an
acknowledgement has been sent.
TRIP / FAIL-QSP acknowledgement by:
– Global-Drive-Control: Click "Trip reset" in dialog box "Diagnostics
9300".
 4, ("Working with the history buffer")
– Keypad 9371 BB:
Press STOP key. Then press RUN to enable the controller again.
– Fieldbus module: Set C0043 = 0
– Control word C0135
– Terminal X5/E5 (default setting) or "DCTRL-TRIP-RESET"
– Control word AIF
– Control word system bus (CAN)
After eliminating the fault, the message is reset automatically.
After eliminating the fault, the warning is reset automatically.
Error messages
Danger notes
If a TRIP source is still active, TRIP cannot be
reset.
The drive restarts automatically if the fault is
eliminated.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9300 vector series

Table of Contents