Troubleshooting and fault elimination
Troubleshooting
Display via the LECOM status word C0150
Bit
0
1
2
3
4
5
6
7
8-11
12
13
14
15
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net
FREE 0
IMP (pulse inhibit)
FREE 2
FREE 3
FREE 4
FREE 5
f
= 0 (actual speed value = 0)
d
RSP (controller inhibit)
Controller status
Warning
Meldung
FREE 14
FREE 15
Meaning
freely combinable
0 = Pulses enabled for power stage
1 = Pulses inhibited for power stage
freely combinable
freely combinable
freely combinable
freely combinable
0 = [n ≠ 0]
1 = [n = 0]
0 = No controller inhibit
1 = Controller inhibit
hex
bin
0
0000
Unit initialisation
1
0001
Switch-on inhibit
3
0011
Operation inhibited (controller inhibit)
6
0110
Operation enabled
7
0111
Message active
8
1000
Active fault
9
1001
Power off
A
1010
Fail-QSP
0 = No warning
1 = Warning
0 = No message
1 = Message
freely combinable
freely combinable