Command
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve
N/A
Firmware
Number
Hardware ID
N/A
Serial Interface Operation
Arguments for
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
Query only.
Returns the firmware type(s) loaded into the unit. The firmware
information is returned in the following format:
FW-AAAAAAA B.B.BB DD/MM/YY
Where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
Example:
<1/FRW?'cr'
>0001/FRW=
Boot:
FW-0000082 0.0.1a 04/09/08
Bulk1:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
Bulk2:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
1 byte
Query only.
Returns the value of the Hardware ID byte.
Example:
<0001/HID?'cr'
>0001/HID=0'cr''lf'
Description of Arguments
5–15
Revision 0
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
FRW=
FRW?
FRW={CR}Bo
ot:{CR}abc{C
R}Bulki:{CR}a
bc{CR}abc
(See
description for
details of
arguments)
HID=
HID?
HID=x
MN-LGAN
LGaN
Query
Need help?
Do you have a question about the LGAN and is the answer not in the manual?
Questions and answers