Command
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve
Maintenance
Status
(Cont)
Retrieve
N/A
Next 5
Unread Stored
Events
Serial Interface Operation
Arguments for
Command or
(Note that all arguments are ASCII
Response to
numeric codes between 48 and 57)
Query
P3V3T=003.3
PN5V8=-00.0
RF24I=000.0
PS24I=-01.5
LNB I=283.4
LNB V=000.0
SW24V=000.0
xx bytes
Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR} Sub-
body{CR}Sub-body,
Where:
Sub-body= ddmmyyhhmmssABCC:
Where:
A being the fault type
SYS= System
RF = RF Module
PS = PS Module
B being the fault/clear indicator.
FLT=Fault
OK=Clear
INF=Info
NA= Not Applicable
MSK= Masked
ALM= Alarm
CC is Fault or Alarm description:
Example:
<1/RNE?
>1/RNE=
06-22-15 11:57:50 PS FLT +13.5V PS
06-22-15 11:57:50 RF ALM Heat Sink Temp
06-22-15 11:57:50 RF FLT BUC LOCK DETECT
06-22-15 11:57:51 PS FLT +24V PS
Description of Arguments
5–28
Revision 0
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
RNE=
RNE?
RNE={CR}AB
CCddmmyyhh
mmss{CR}AB
CCddmmyyhh
mmss{CR}AB
CCddmmyyhh
mmss{CR}AB
CCddmmyyhh
mmss{CR}AB
CCddmmyyhh
m
mss
(See
description for
details of
arguments)
MN-LGAN
LGaN
Query
Need help?
Do you have a question about the LGAN and is the answer not in the manual?