6.1

NC RACK

POWER SUPPLY UNIT (MODEL CPS-12N, MODEL CPS-16F)
6.1.1
MOUNTING SCREW -
INDICATION
R e m o v a l
(1)
(b)
(2) Installation
( a )
( b )
( c )
144
LAMP
{
CONNECTOR
Model CPS-12N
Check that AC input power is not supplied [the
SOURCE indication lamp (green) of the power
supply unit is off], then pull out the CN03, CN04,
and CN05 cables.
Loosen the mounting screws in the three positions
in the figure and r;move the power suppiy unit
from the NC rack.
Insert the power supply unit in line with the guide
of the NC rack.
Loosen the mounting screws in the three positions
in the figure.
Insert the CN03, CN04, and CN05 cables into the
original positions.
. 0 ~
SCREW
INDICATION
LAMP
{
.
Model CPS-16F
SCREW
CONNECTOR
s c R E w