TROUBLESHOOTING WITHOUT ALARM CODES
4.3
Cause of Trouble
Power is not supplied
to HANDLE PG.
Two or three handles
HANDLE PG trouble
FC903 board trouble
Manual pulsing
magnification input is
selected.
Others: Related para-
meters
114
Table 4.33 (Cent'd)
check Method~
'his is a counter monitor.
Manual pulsing magnification
input 1/0 signal #3002
I
I
D 6
M P4
MP2
MP1
o
0
o
0
1
0
1
Either O or 1
1
The max s~eed in HANDLE mode
mode
Optional magnification setting at magnifica-
tion X 100 selection time
(For pm2003 D,= 1)
I
D 5
cation
0
x
l
x
1 0
1
0
x
1 0 0
1
x 100
Verify it with the para-
meter table attached at
the factory prior to
(Cent'd)
Solution
shipment.