4.3 TROUBLESHOOTING WITHOUT ALARM CODES

4.3.12 EDIT DOES NOT FUNCTION

Cause of Trouble
Erroneous input signal
(a) The edit lock signal
is entered.
(b) The setting edit 10cI
signal is entered.
A
parameter to lock a
specially numbered
program is turned on.
Others:
(a) Memory capacity
exceeded
(b) Stored program
volume exceeded
(c) Overlapped stored
program number~
124
Table 4.41
Edit Does Not Function
C h e c k M e t h o d
PROGRAM OVER!
ALREADY IN!
(Cent'd)
Solution
Select the edit lock release.
Set setting pmOOOO D, to O.
For the procedure, refer to
YASNAC i80M Instruction
Manual (TOE-C843-11.30)
and YASNAC i80L Instruc
tion Manual (T0E-C843-
11.20).
This is a setting to prevent
programs from being
destroyed by erroneous edit
operation. For modification
Manual (TOE-C843-11.30)
and YASNAC i80L Instruc.
tion Manual (T0E-C843-
11.20).
. Refer to YASNAC i80M
Instruction Manual
(TOE-C843-11.30) and
" Part Program Editing"
of the YASNAC i80L
Instruction Manual
Continue the edit
operation after erasing
unnecessary programs.