Adjusting The Accelerator Position Sensor - Yamaha TRACER MT09TRA Service Manual

Hide thumbs Also See for TRACER MT09TRA:
Table of Contents

Advertisement

2
1
g. Press the "TCS" button "1" to select the diag-
nostic mode "DIAG" "3" or the CO adjustment
mode "CO".
1
h. After selecting "DIAG", simultaneously press
the "TCS" button "1" and "RESET" button "2"
for 2 seconds or more to execute the selec-
tion.
TIP
The diagnostic code number "01" appears on
the multi-function meter right display.
2
1
i. Diagnostic code number "01" is selected.
j. Adjust the position of the throttle position sen-
sor angle so that 11–21 can appear in the
meter right display.
k. After adjusting the throttle position sensor an-
gle, tighten the throttle position sensor
screws "4".
Throttle position sensor screw
3.5 Nm (0.35 m·kgf, 2.5 ft·lbf)
SELECT
3
DIAG
DIAG
DIAG
01
DATA
15
7-12
THROTTLE BODIES
4
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS30486
ADJUSTING THE ACCELERATOR POSITION
SENSOR
EWA16700
WARNING
• Handle the accelerator position sensor with
special care.
• Never subject the accelerator position sen-
sor to strong shocks. If the accelerator po-
sition sensor is dropped, replace it.
1. Check:
• Accelerator position sensor
Refer to "CHECKING THE ACCELERATOR
POSITION SENSOR" on page 8-145.
2. Adjust:
• Accelerator position sensor angle
TIP
Before adjusting the accelerator position sensor,
the throttle bodies must be removed.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Temporary tighten the accelerator position
sensor.
b. Check that the throttle valves are fully closed.
c. Connect the accelerator position sensor to
the wire harness.
d. Connect the throttle cables to the throttle bod-
ies.
e. Turn the main switch to "OFF".
f. Simultaneously press and hold the "TCS"
button "1" and "RESET" button "2", turn the
main switch to "ON", and continue to press
the buttons for 8 seconds more.
TIP
"ECU" appears on the multi-function meter right
display.
g. Simultaneously press the "TCS" button "1"
and "RESET" button "2" for 2 seconds or
more.
TIP
"DIAG" appears on the multi-function meter right
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracer mt09traf

Table of Contents