Yamaha TRACER MT09TRA Service Manual page 520

Hide thumbs Also See for TRACER MT09TRA:
Table of Contents

Advertisement

Check each switch for continuity with the pocket tester. If the continuity reading is incorrect, check the
wiring connections and if necessary, replace the switch.
ECA14371
NOTICE
Never insert the tester probes into the coupler terminal slots. Always insert the probes from the
opposite end "a" of the coupler, taking care not to loosen or damage the leads.
TIP
• Before checking for continuity, set the pocket tester to "0" and to the "  1" range.
• When checking for continuity, switch back and forth between the switch positions a few times.
The switches and their terminal connections are illustrated as in the following example of the main
switch.
The switch positions "a" are shown in the far left column and the switch lead colors "b" are shown in the
top row.
The continuity (i. e., a closed circuit) between switch terminals at a given switch position is indicated by
"
".
There is continuity between red/white, brown/blue and brown/red when the switch is set to "ON".
There is continuity between red/white and brown/red when the switch is set to "P".
ELECTRICAL COMPONENTS
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
8-129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracer mt09traf

Table of Contents