• Make sure all connections are tight.
4. Check:
• Continuity
(with the pocket tester)
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
TIP
• If there is no continuity, clean the terminals.
• When checking the wire harness, perform
steps (1) to (3).
• As a quick remedy, use a contact revitalizer
available at most part stores.
BASIC SERVICE INFORMATION
5. Check:
• Resistance
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
TIP
The resistance values shown were obtained at
the standard measuring temperature of 20 C
(68 F). If the measuring temperature is not
20 C (68 F), the specified measuring condi-
tions will be shown.
Intake air temperature sensor re-
sistance
5.40–6.60 k at 0 C (32 F)
290–390  at 80 C (176 F)
1-39