Fault code
Possible cause
The batteries need charging, or there is a bad connection to the battery. Check the connections to the
battery. If the connections are good, try charging the batteries.
The left hand motor has a bad connection. Check the connections to the left hand motor.
The left hand motor has a short circuit to a battery connection. Contact your Sunrise Medical authorised
dealer.
The right hand motor has a bad connection. Check the connections to the right hand motor.
The right hand motor has a short circuit to a battery connection. Contact your Sunrise Medical authorised
dealer.
The wheelchair is being prevented from driving by an external signal. One possibility is that the battery
charger is plugged in.
A joystick fault is indicated. Make sure that the joystick is in the centre position before switching on the
control system.
A control system fault is indicated. Make sure the control system connections are secure.
The parking brakes have a bad connection. Check the parking brake and the motor connections. Make sure
that the control system connections are secure.
An excessive voltage has been applied to the control system. This is usually caused by a poor battery
connection. Check the battery connections.
S = Speed indicator LED's
A communication fault is indicated. Make sure that the joystick cable is securely connected and not
+ S
damaged.
A = Actuator LED's
An actuator trip is indicated. If more than one actuator is fitted, check which actuator is not working.
+ A
Check the actuator wiring.