PGV...-F200/-F200A...-B6-V15B

Operation and Communication

7.1.6

Global Primary Data

Global primary data allows you to parameterize the reader using PROFIBUS. Global primary
data is always transferred to the reader in full.
Designation
X resolution
Y resolution
Angle resolution
Horizontal offset
Vertical offset
Angle offset
No position value X X value if no code tape is visible
No position value Y Y value if no code tape is visible
No position value
angle
Bandwidth
Color
Table 7.2
44
Function
Multiplier for the length in the
direction of the X coordinate
Multiplier for the length in the
direction of the Y coordinate
Multiplier for the angle output
Offset in the direction of the X
coordinate
Offset in the direction of the Y
coordinate
Line of vision offset
Angle output if no colored tape is
visible
Width of the colored tape
Color of the tape
Bold = default values
Parameter data
Primary data
Resolution
0.1 mm
1 mm
10 mm
Resolution
0.1 mm
1 mm
10 mm
Resolution
-16,384 – 0 –
16,384
360
Length
0 mm –
±10,000,000 mm
0 mm –
Length
±10,000,000 mm
Angle
-16,383 – 0 –
16,383
X data at "No
Last valid
Position"
position
specified value
(0 – 0xFFFF
FFFF
hex
Y data at "No
Last valid
Position"
position
specified value
(0 – 0xFFFF
FFFF
hex
Angle data at "No
Last valid angle
specified angle
Position"
(0 – 0xFFFF
Width
10 mm – 40 mm
18 mm
Color
1 = blue (RAL
5015)
2 = green (RAL
6032)
3 = red (RAL
3001)
4 = Yellow (RAL
1021)
)
)
)
hex