Service Training
2.6.7.1.4
CONTROL OF THE VARIOUS WORK FUNCTIONS
All speeds of the working hydraulics can be regulated with infinitely-variable control. A distance sensor in
each valve block of the control valve block senses how far the control lever in question has been moved and
then sets the motor speed via the electronic control accordingly.
The motor speed is sensed with the speed sensor in the pump motor and adjusted as required. The output
signal of the distance sensors 2B11, 2B12, 2B13 and 2B14 ranges from 3.75 V to 11.25 V.
Section
2.6
Page
63