Fan; Speed Sensor - Linde E25 Service Training

Electric fork truck
Hide thumbs Also See for E25:
Table of Contents

Advertisement

Section
2.1
Page
8
2.1.5

FAN

Fan method of operation to 6/95:
The traction motors and pump motor are forced-air ventilated by axial-flow fan 9M1. When the operating
temperature of one of the three motors exceeds 80 °C, battery negative is applied to the fans via three thermal
switches (1B4, 1B5 and 2B5) connected in parallel. The fans are supplied with 24 V direct current over voltage
converter U1. The 80 °C thermal (make) switches are mounted on the motor brush holders.
Fan method of operation from 7/95:
In contrast to the above fan method of operation up to 6/95, thermal sensors 6B1, 6B2 and 6B3 are mounted
on the brush holders of the traction motors and pump motor. When the temperature in one of the three motors
exceeds 80 °C, +24 V is applied to axial-flow fan 9M1 and 9M2 via the combined instrument.
NOTE:
The fan operates only when the key switch is turned on, i.e. the fan does not run when the key
switch is turned off.
SPECIFICATIONS FOR FAN 9M1
Rated voltage:
Voltage range:
Power consumption:
Power:
Temperature range:
Rated speed:
2.1.6

SPEED SENSOR

A differential speed sensor (1B8) is installed on the left-hand motor. The speed sensor senses the brake
disc bridges and supplies information regarding the motor speed and direction of rotation.
Adjustment:
The speed sensor is mounted on an angle plate on the inside bearing plate. The air gap between the active
sensor area and a web on the brake disc must be 1.0+0.3 mm.
24 V
12 - 24 V
710 mA
17 W
-20 ... +72 ° C
3400 rpm