2.6.11.1.1 PROGRAMMING OF MENU FUNCTIONS 11 TO 24

-
Connect the diagnostic unit to the truck data connector. The data connector is located behind the
left switch cover at the instrument panel.
-
Turn on the key switch.
-
Depress the EIN (on) button. If the internal batteries are OK, the following message will appear on
the display
-
After the battery test there will appear
-
Depress the DATEN NEU (new data) button.
-
Enter the menu number.
-
The selected menu number (MN) will appear and the current value (EW).
-
The programmed value can be modified with the + and - buttons. The new value (NW) will appear
in the second line of the display.
-
Depress the ENTER button to store the new value (NW).
-
The newly programmed value (PW) appears in the third line of the display.
Batterie OK
*Linde Test Module**
** Version 2.94 **
** Device Ready **
* No Data received *
MN
EW
NW
MN
EW
NW
PW
* Data end *