GE Agile P50 Series Technical Manual page 47

Compact feeder protection relay
Table of Contents

Advertisement

P50 Agile P153
SYSTEM DATA
2.3.2
Main Menu Contents
SYSTEM DATA
VIEW RECORDS
MEASUREMENTS
CB CONTROL
DATE AND TIME
CONFIGURATION
TRANS. RATIOS
RECORD CONTROL
P153/EN M/B
Password protected window for "SYSTEM DATA'' setting i.e. Language,
Description, Model Number, Serial Number, Software Version,
Frequency, USB Address, USB Parity, USB Baud Rate, Password,
Active Group, Opto I/P Status, Relay O/P Status. CB Open/Close, Opto
I/P and Config Port.
This menu is to view Fault Record, Event Record, Maint Record and
Alarm records.
This menu displays the measurements values of various parameters (i.e.
Phase current, measured and derived earth current, negative, positive
phase sequence current and I2/I1 ratio as per per phase / earth CT ratio,
TC (Trip Counter), BOC (Breaker Operation Counter), BOT (Breaker
Operating Time) and Th State (Thermal State).
Password protected window for "CB CONTROL" settings i.e. TCS
Alarm, TCS Timer, CB Open S'vision (Enabled / Disabled), CB Open
Time, CB Open Alarm (Enabled / Disabled), CB Open Oper, CB Control
By, Close Pulse Time, Open Pulse Time .
Password protected window for "DATE AND TIME'' settings i.e. Local
Time Enable, Local Time Offset. DST Enable, DST Offset, DST Start,
DST Start Day, DST Start Month, DST Start Mins, DST End, DST End
Day, DST End Month, DST End Mins, RP Time Zone, SET Hours, SET
Minutes, SET Seconds, SET Date, SET Month and SET Year.
Password protected window for "CONFIGURATION'' settings i.e.
Restore Defaults, Active Settings, Copy From, Copy To, Setting Group 1
(Enabled/Disabled), Setting Group 2 (Enabled/Disabled), System Config
(Enabled/Disabled), Overcurrent (Enabled/Disabled), Neg Sequence
O/C (Enabled/Disabled), Broken Conductor (Enabled/Disabled), Earth
Fault 1 (Enabled/Disabled), Earth Fault 2 (Enabled/Disabled), Thermal
Overload (Enabled/Disabled), Cold Load Pickup (Enabled/Disabled),
Measure't Setup, UnderCurr Prot (Enabled/Disabled), CB Fail
(Enabled/Disabled) and Setting Values.
Password protected window for "TRANS. RATIO '' settings i.e Phase
CT Primary, Phase CT Sec'y, E/F CT Primary and E/F CT Secondary.
Password protected window for "RECORD CONTROL'' settings i.e.
Clear Events (Yes/No), Clear Faults (Yes/No), Clear Dist Recs (Yes/No),
Clear Maint (Yes/No), Thermal Reset (Yes/No).
5 Configuration
5-9