P50 Agile P153
Figure 4: Correct polarity of battery
Only use Panasonic make Lithium battery type BR2032 or equivalent with a nominal voltage
of 3 V.
7.
Ensure that the battery is held securely in its socket and that the battery terminals make good
contact with the socket terminals.
8.
Replace the front bazel and relay cover.
9.
After replacing the lithium coin battery, you must reconfigure and reset the system date and
time.
2.3
Replacing the Unit
If your product should develop a fault while in service, depending on the nature of the fault, the error
codes will be generated which can be viewed on the relay HMI. First step is to take actions as
suggested in the Troubleshooting section of this manual. In the unlikely event that the problem persist
or lies with the wiring and/or terminals, then you must replace the complete device, rewire and re-
commission the device.
Once the unit has been reinstalled, it should be re-commissioned.
Caution:
Caution: Before carrying out any work on the equipment, you should be familiar with the
Warning:
Note:
P153/EN M/B
If the repair is not performed by an approved service centre, the warranty will
be invalidated.
contents of the Safety Information section of this guide or the Safety Guide
Pxxx-SG-4LM-3 as well as the ratings on the equipment's rating label. This
should ensure that no damage
electronic components.
Before working at the rear of the unit, isolate all voltage and current supplying
it.
P153 does not support automatic current transformer shorting. Therefore, for safety reasons CT
terminals to be shorted when the terminal block is removed.