Axial and radial run‐out tolerances
To ensure that the torque flange retains its characteristics once it is installed,
we recommend that the customer also chooses the specified form and posi-
tion tolerances, surface quality and hardness for the connections provided.
HBM
0.02 AB
0.02 AB
Internal centering
Flange A
Hardness 47 2 HRC
0.8
Surface quality of the axial and radial
run‐out tolerances (A, B and AB)
0.02 AB
Flange B
T40FM