OPERATION
Command 48, Additional Device Status Bytes
Table 12
below summarizes the Command 48 Additional Device Status bytes. This is a 6-byte field. The remaining status bytes are
reserved for future use. A status bit is cleared (0) for no error. A status bit is set (1) when an error (or condition) is detected.
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
70
Table 12 – Command 48, Additional Device Status Bytes Bit Assignments
Bit
Error/Status Description
0
Serious Device Error
1
Electronics Hardware Failure
2
Memory Error
3
Measurement Failure
4
Maintenance Required
5
FRAM Failure
6
Power Supply Failure
7
Configuration Invalid
0
Device Initialization Failed
1
Device Not Initialized
2
Electronic Temperature Too High
3
Flow Sensor Failure
4
Flow Sensor Not Connected
5
Sensor Communication Failure
6
Totalizer Overflow
7
Flow Is Out Of Range
0
Ethernet Communication Failure
1
USB Communications Failure
2
Industrial Communication Protocol Fail
3
Process Temperature Over Max Limit
4
Process Temperature Under Min Limit
5
Flow Sensor Heater Shorted
6
Not Used
7
Flow Sensor Heater Open
0
Not Used
1
Not Used
2
Flow Sensor A/D Counts Under Min Limit
3
Flow Sensor Delta-R Below Min Limit
4
FE Flow Above Limit
5
FE Process Temperature Over Min Limit
6
FE Process Temperature Under Max Limit
7
Component Error – TMP100
0
Component Error – LTC2654
1
Component Error – CORE 4-20 mA Input
ADS1100 (non-fatal)
2
Not Used
3
I2C0 Failure
4
Component Error – Heater Monitor A/D
5
Component Error – 16-Bit I/O Expander
6
Component Error – Delta-R A/D Failure
7
Component Error – Reference-R A/D Failure
0
Component Error -- FE FRAM
1
Component Error -- Active Excitation IC
2
Component Error -- Reference Excitation IC
3
STACK in Self Check Mode No Process Data
Available
4
Not Used
5
Not Used
6
Not Used
7
FE in Internal Delta-R Check – process data not
reliable (non-fatal)
MT100 Multipoint Flow Meter
Class
Device Status Bits Set
Hardware
Hardware
Hardware
Hardware
4, 7
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
4, 7
Hardware
4,7
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Hardware
Fluid Components International LLC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Advertisement

Table of Contents
loading

Table of Contents