INSTALLATION

Install Flow Element

Duct Flange Installation (MT100M)
Install the duct mount flow element assembly as appropriate to its configuration. Refer to
information specific to the unit's serial/tag number.
Follow these steps to install the flow element.
1. The exact placement of the flow element is typically predetermined at the time of order. Use hole pattern and hole sizes as shown in
Figure
4, page
in
Figure
5, page
Note:
2. Using supplied end support mounting kit hardware, install flow element's end support as shown in
support securing bolts (6 ea. 5/16-24UNF x .875 lg).
3. Carefully place flow element in process duct with flow arrow pointing in direction of process media flow and with reference flat parallel
to flow. Insert end of flow element assembly standpipe into end support sleeve.
4. Using supplied duct flange mounting kit hardware, install flow element to process duct as shown in
torque sequence shown in
10 ft-lbs (13.6 N-m).
5. With flow element assembly standpipe captured within end support sleeve loosely install 1/2-13UNF x 2-inch long bolt (included in
optional end support mounting kit) into end support sleeve, engaging flow element standpipe (see
installation method that uses a reinforcement plate if the supplied anchor nuts are not adequate for the application.) Using star pattern
bolt torque sequence shown in
at 10 ft-lbs (13.6 N-m).
6. Torque end support sleeve bolt to 37 ft-lbs (50.2 N-m).
Note:
8
9
to drill holes for flow element duct mount flange. On opposite side of duct use hole pattern and hole sizes as shown
10
to drill holes for flow element duct mount end support.
End support is secured to duct via anchor nuts supplied in end support mounting kit.
Figure 4
gradually torque duct flange securing bolts (6 ea. 5/16-24UNF x .875 lg) with final bolt torque at
Figure 4
gradually torque end support securing bolts (6 ea. 5/16-24UNF x 1.0 lg) with final bolt torque
For the alternative installation method, the reinforcement plate with drilled, tapped holes is customer-supplied. Refer
to
Figure 6
and
Figure
7. Longer bolts (typically 1-inch long) may be needed when the reinforcement plate is used.
MT100 Multipoint Flow Meter
APPENDIX
A, page
97
for configuration
Figure
5. Loosely torque end
Figure
4. Using star pattern bolt
Figure
5). (Note: Use the alternative