TS11/TS15, Technical Data
7.8
7.8.1
Accuracy
Initialisation

SmartStation

SmartStation Accuracy

Measurement precision and accuracy in position and accuracy in height are
dependent upon various factors including the number of satellites tracked, constel-
lation geometry, observation time, ephemeris accuracy, ionospheric disturbance,
multipath and resolved ambiguities. Figures quoted assume normal to favourable
conditions.
Position accuracy:
Method:
Reliability of initialisation:
Time of initialisation:
Range:
* Might vary due to atmospheric conditions, signal multipath, obstructions, signal
geometry and number of tracked signals.
Horizontal: 5 mm + 0.5 ppm
Vertical: 10 mm + 0.5 ppm
When used within reference station networks the posi-
tion accuracy is in accordance with the accuracy specifi-
cations provided by the reference station network.
Leica SmartCheck+ technology
Better than 99.99 %
Typically 8 s*
Up to 50 km*