TS11/TS15, Description of the System
Term
Description
PinPoint
PinPoint refers to the Reflectorless EDM technology which
enables an increased measuring range with a smaller laser spot
size. Three options are available: R30, R400 and R1000.
EGL
Electronic Guide Light
An EGL fitted to an instrument assists with prism targeting. It
consists of two differently coloured flashing lights located in the
instrument telescope housing. The person holding the prism can
align themselves into the line-of-sight of the instrument.
Motorised
Instruments fitted with internal motors, enabling automatic hori-
zontal and vertical turning are referred to as Motorised.
ATR
Automated Target Aiming.
ATR refers to the instrument sensor which enables the automatic
target aiming to a prism.
Instruments fitted with Target aiming are referred to as Auto-
Automated
mated.
Target aiming refers to the instrument sensor which enables the
automatic target aiming to a prism.