Atmospheric condi-
tions
Accuracy
Characteristics
Laser dot size
TS11/TS15, Technical Data
D:
Object in strong sunlight, severe heat shimmer
E:
Object in shade, sky overcast
F:
Underground, night and twilight
Standard measuring
0 m - 500 m
>500 m
Object in shade, sky overcast. Beam interruptions, severe heat shimmer and moving
objects within the beam path can result in deviations of the specified accuracy. The
display resolution is 0.1 mm.
Type:
Carrier wave:
Measuring system:
Distance [m]
at 30
at 50
std. dev.
Measure time,
ISO 17123-4
typical [s]
2 mm + 2 ppm
3 - 6
4 mm + 2 ppm
3 - 6
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
Laser dot size, approximately [mm]
7 x 10
8 x 20
Measure time,
maximum [s]
12
12