TS11/TS15, Check & Adjust
4.8
Adjustment
Adjustment

Adjusting the Laser Guide

To avoid moisture or dust entering the Laser Guide compartment, adjustment screws
and screw covers must be fixed after each adjustment procedure.
The recommended adjustment procedure is designed for distances of 50 m and
120 m. Use the adjustment drawing, which is showing a TS15 G telescope, with
crosshairs for line of sight and Laser Guide. Look trough the telescope and aim to the
crosshairs of the telescope. For well-adjusted Laser Guides, the laser beam should
exactly match the circles for 50/120 m.
Make sure, adjustment screws are accessible during adjustment.
Make sure, the position of the telescope remains still. Check the target by looking
trough the telescope.
Adjustment procedure might be repeated to achieve high precision adjustment.
Please enlarge this target plate to 200% prior to using it for adjustment.