Operate in API mode

Receive Packet frame - 0x90

Description
When a device configured with a standard API Rx Indicator (AO = 0) receives an RF data packet, it
sends it out the serial interface using this message type.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data fields
Frame type
64-bit source address
Reserved
Receive options
Received data
Example
In the following example, a device with a 64-bit address of 0x0013A200 40522BAA sends a unicast
data transmission to a remote device with payload RxData. If AO=0 on the receiving device, it sends
the following frame out its serial interface.
Frame data fields
Start delimiter
Length
Frame type
XBee 868LP RF Modules User Guide
Offset
Description
3
0x90
4-11
The sender's 64-bit address. MSB first, LSB last.
12-13
Reserved.
Bit field:
14
0x00 = Packet acknowledged
0x01 = Packet was a broadcast packet
0x06, 0x07:
b'01 = Point-Multipoint
b'10 = Repeater mode (directed broadcast)
b'11 = DigiMesh (not available on the 10K
product)
Ignore all other bits.
15-n
The RF data the device receives.
Offset
0
MSB 1
LSB 2
3
Frame data
API frame
Example
0x7E
0x00
0x12
0x90
193