C0520: Fuser overheat

<Detection Timing>
• The temperature detected by the Thermistor remains higher than 235 °C for a predeter-
mined period of time while the fusing temperature control is being provided.
<Troubleshooting Procedures>
Fusing Unit
Thermistor (TH1)
Fusing Roller Heater Lamp (H1)
Step
1
Replace Thermistor (TH1).
2
Replace Fusing Roller Heater
Lamp (H1).
3
Replace Thermostat (TS1).
4
Replace Fusing Unit.
5
Replace Controller/Mechanical
Control Board (PWB-P).
6
Replace Power Unit (PU1).
(6)

C0650: Scanner home sensor error

<Detection Timing>
• The Scanner Home Position Sensor is not detected within the predetermined period of
time after the Scanner Motor has started turning.
<Troubleshooting Procedures>
Scanner Motor (M4)
Step
Action
1
M4 operation check
2
Replace PWB-P.