Automatic Document Feeder Sub-Scanning Zoom Ratio Adjustment - Konica Minolta Di1610 Service Manual

Hide thumbs Also See for Di1610:
Table of Contents

Advertisement

(6)

Automatic Document Feeder Sub-Scanning Zoom Ratio Adjustment

<Reference>
C
Zoom Ratio
Specification
Full Size
200 ± 0.5 mm "ADJUST" menu ADF SUB ZOOM
(100%)
<Adjustment Procedure>
1. Print the test pattern.
2. Enter the "ADJUST" menu in the Service mode.
3. Load the test pattern into the Automatic Document Feeder and make a test copy.
NOTE
• The test pattern should be positioned vertically.
• Use A4 L or Letter L paper loaded into Tray 1 to make the test copy.
4. If the length of C in the copy of the test pattern is not the same as the length of C in the
test pattern, adjust it according to the following procedure.
5. Change the setting.
If the width of C in the test pattern is longer than the specified width . . . . .
Decrease the setting.
If the width of C in the test pattern is shorter than the specified width . . . . .
Increase the setting.
✽ If the shift cannot be adjusted to within the specification with a single adjustment, perform
the adjustment again to change the setting.
6. Press the Yes key to apply the setting.
<If A is shorter than B>
Using a coin, loosen the shoulder screw shown in the
illustration, and then slide the scale on the Automatic
Document Feeder away from you.
NOTE
• After finishing the adjustment, be sure to tighten
1382U029AA
the loosened shoulder screw.
• Adjust the length of C in the copy of the test pat-
tern so that the following specification is met.
1382D009AA
Mode
D-12
Function
Setting Range
95 to 105
1 increment = 0.4%