(2)

Adjust

Function
TEST
COPY
PRN
MAIN
REGIST
ADJUST
TEST
COPY
PRN
SUB
REGIST
ADJUST
TEST
COPY
CCD
MAIN
ZOOM
ADJUST
TEST
COPY
CCD
SUB
ZOOM
ADJUST
TEST
COPY
CCD
MAIN
REGIST
ADJUST
Purpose
To vary and adjust the print start
position in the main scanning
direction.
✽ If the image on the copy deviates
in the CD direction
✽ When the PH unit has been
replaced
To vary and adjust the print start
position in the sub-scanning direc-
tion.
✽ If the image on the copy deviates
in the FD direction
✽ When the PH unit has been
replaced
To adjust for variations in the accu-
racy of IR parts and their mounting
accuracy by varying the scanning
zoom ratio in the main scanning
direction.
✽ When the Timing Belt has been
replaced
✽ When the Scanner Assy. has
been replaced
To adjust for variations in the accu-
racy of IR parts and their mounting
accuracy by varying the scanning
zoom ratio in the sub-scanning
direction.
✽ When the Scanner Assy. has
been replaced
To adjust for variations in the accu-
racy of IR parts and their mounting
accuracy by varying the scanning
start position in the main scanning
direction.
✽ When the Upper Cover Assy.
(Original Glass) has been
replaced
✽ When the Scanner Assy. has
been replaced
S-14
Setting Details/Precautions
Press the Start key to begin
printing the test page.
The setting range is 60 to 140.
(1 increment = 0.1 mm)
Press the Start key to begin
printing the test page.
The setting range is 87 to 113.
(1 increment = 0.46 mm)
Press the Start key to begin
printing the test page.
The setting range is 95 to 105.
(1 increment = 0.4%)
Press the Start key to begin
printing the test page.
The setting range is 95 to 105.
(1 increment = 0.4%)
Press the Start key to begin
printing the test page.
The setting range is 90 to 110.
(1 increment = 0.5 mm)