HBD PV500-0007M1 User Manual page 61

Solar pump inverter
Table of Contents

Advertisement

PV500 series solar pumping inverters
Function
code
P18.11
Current pump flow Unit: cubic meter/hour
P18.12
Current pump lift
MSBs in total pump
P18.13
LSBs in total pump
P18.14
Total pump flow
P18.15
P19 Group Voltage boost (converter module communicates with boost module
through 485)
Boost voltage loop
P19.00
Boost voltage loop
P19.01
Boost current loop
P19.02
P19.03
Boost current loop 0.000~65.535
Name
Detailed illustration of parameters
1: AC grid power supply
Tens on LED
0: Detection indicates the system
contains the boost module.
1: Detection indicates the system does
not contain the boost module.
Unit: meter
This function code displays the 16 most
significant bits (MSBs) in the total pump
flow
flow. Unit: cubic meter
This function code displays the 16 least
significant bits (LSBs) in the total pump
flow
flow. Unit: cubic meter. Total pump flow =
P18.13*65535+ P18.14
Setting this value to 1 can reset the total
pump flow. P18.13 and P18.14 will
accumulate the flow after resetting. After
resetting
the resetting succeeds, P18.15 is
automatically set to 0.
0.000~65.535
KP
0.000~65.535
KI
0.000~65.535
KP
-59-
Function parameters
Default Modify
0.0
0.0
0
0.0
0
0.500
0.080
0.010
0.010