PV500 series solar pumping inverters
Function
code
QUICK/JOGthe
shifting sequence
P07.03
of running
command
STOP/RST
P07.04
stop function
Boost module
P07.11
temperature
Name
Detailed illustration of parameters
inverter does not record the state after
shifting during powering off. The inverter
will run according to parameter P00.13
during next powering on.
When P07.02=6, set the shifting
sequence of running command channels.
0: Keypad control→terminal control
→communication control
1: Keypad control←→terminals control
2: Keypad control←→communication
control
3: Terminals control←→communication
control
Select the stop function by STOP/RST.
STOP/RST is effective in any state for the
keypad reset.
0: Only valid for the keypad control
1: Both valid for keypad and terminals
control
2: Both valid for keypad and
communication control
3: Valid for all control modes
When the inverter is configured with the
boost module, this function code displays
the temperature of this module. This
function code is valid only in the AC mode.
This function code is invalid in the PV
mode.
-42-
Function parameters
Default Modify
1
1