PV500 series solar pumping inverters
Function
code
Converter module
P07.12
temperature
MSB of inverter
P07.15
consumption
LSB of inverter
P07.16
consumption
P07.27
Current fault type
Previous fault
P07.28
Previous 2 fault
P07.29
Previous 3 fault
P07.30
Previous 4 fault
P07.31
Previous 5 fault
P07.32
Previous 6 fault
P07.57
Previous 7 fault
P07.58
Previous 8 fault
P07.59
P07.60
Previous 9 fault
Name
Detailed illustration of parameters
-20.0~120.0°
-20.0~120.0°
Display the power used by the inverter.
power
Inverter power
consumption=P07.15*1000+P07.16
Setting range of P07.15: 0~65535(*1000)
Setting range of P07.16: 0.0~999.9
power
Unit: kWh
0:No fault
1:IGBT U phase protection(OUt1)
type
2:IGBT V phase protection(OUt2)
3:IGBT W phase protection(OUt3)
type
4:OC1
5:OC2
type
6:OC3
7:OV1
type
8:OV2
9:OV3
type
10:UV
11:Motor overload(OL1)
type
12:The inverter overload(OL2)
13:Input side phase loss(SPI)
type
14:Output side phase loss(SPO)
15: Overheat of the boost module (OH1)
type
16: Overheat fault of the inverter
module(OH2)
-43-
Function parameters
Default Modify
●
●
●
●
●
●
●
●
●
●
●
●
●