HBD PV500-0007M1 User Manual page 30

Solar pump inverter
Table of Contents

Advertisement

PV500 series solar pumping inverters
Function
code
Lower limit of the
P00.05
running frequency
P00.11
ACC time 1
P00.12
DEC time 1
Running direction
P00.13
selection
Name
Detailed illustration of parameters
the upper limit of the output frequency of
the inverter which is lower than or equal to
the maximum frequency.
Setting range: P00.05~P00.03 (Max.
output frequency)
The lower limit of the running frequency is
that of the output frequency of the inverter.
The inverter runs at the lower limit
frequency if the set frequency is lower
than the lower limit.
Note: Max. output frequency ≥ Upper limit
frequency ≥ Lower limit frequency
Setting range: 0.00Hz~P00.04 (Upper
limit of the running frequency)
ACC time means the time needed if the
inverter speeds up from 0Hz to the Max.
output frequency (P00.03).
DEC time means the time needed if the
inverter speeds down from the Max.
Output frequency to 0Hz (P00.03). PV500
series inverters have four groups of
ACC/DEC time which can be selected by
P05. The factory default ACC/DEC time
of the inverter is the first group.
Setting range of P00.11 and P00.12:
0.0~3600.0s
0: Runs at the default direction. The
-28-
Function parameters
Default Modify
0.00Hz
Depend
on mode
Depend
on mode
0