HBD PV500-0007M1 User Manual page 37

Solar pump inverter
Table of Contents

Advertisement

PV500 series solar pumping inverters
Function
code
frequency point 1
P04.03
of motor 1
voltage point 1 of
P04.04
frequency point 2
P04.05
of motor 1
voltage point 2 of
P04.06
frequency point 3
P04.07
of motor 1
voltage point 3 of
P04.08
Name
Detailed illustration of parameters
Output voltage
V
b
V
Setting range of P04.01: 0.0%:
(automatic) 0.1%~10.0%
Setting range of P04.02: 0.0%~50.0%
V/F
If P04.00 =1, the user can set V//F curve
by P04.03~P04.08.
V/F is set to the motor load.
Note: V1<V2<V3; f1<f2<f3. If the low-
V/F
frequency voltage is high,
overtemperature and burning may occur
motor 1
and the overcurrent stall and protection
may occur to the inverter.
V/F
V/F
motor 1
Setting range of P04.03: 0.00Hz~P04.05
Setting range of P04.04: 0.0%~110.0%
V/F
(rated voltage of motor1)
Setting range of P04.05: P04.03~P04.07
Setting range of P04.06:
V/F
0.0%~110.0%(rated voltage of motor1)
Setting range of P04.07:
motor 1
f
f Output frequency
b
-35-
Function parameters
Default Modify
0.00Hz
00.0%
00.00
Hz
00.0%
00.00
Hz
00.0%