PV500 series solar pumping inverters
Function
code
Voltage ratio of V
P04.35
P05 Group Input terminals
P05.00
HDI input type
DI1 terminals
P05.01
function selection
DI2 terminals
P05.02
function selection
DI3 terminals
P05.03
function selection
DI4 terminals
P05.04
function selection
DI5 terminals
P05.05
function selection
HDI terminals
P05.09
function selection
Name
Detailed illustration of parameters
0.00~2.00
and U
0: High-speed pulse input. See
P05.49~P05.54.
1: HDI switch input
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Operation pause
9: External fault input
10: Increasing frequency setting(UP)
11: Decreasing frequency setting(DOWN)
12: Cancel the frequency change setting
13: Shift between A setting and B setting
14: Shift between combination setting and
A setting
15: Shift between combination setting and
B setting
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
-37-
Function parameters
Default Modify
1.40
1
42
43
44
45
1
46