PV500 series solar pumping inverters
Function
code
Max. output
P00.03
frequency
Upper limit of the
P00.04
running frequency
Name
Detailed illustration of parameters
rotating, jogging and fault reset.
0: Keypad running command
channel("LOCAL/REMOT" light off)
Carry out the command control by RUN,
STOP/RST on the keypad.
Set the multi-function key QUICK/JOG to
FWD/REV shifting function (P07.02=3) to
change the running direction; press RUN
and STOP/RST simultaneously in running
state to make the inverter coast to stop.
1: Terminal running command channel
("LOCAL/REMOT" flickering)
Carry out the running command control by
the forward rotation, reverse rotation and
forward jogging and reverse jogging of the
multi-function terminals.
2: Communication running command
channel ("LOCAL/REMOT" on);
The running command is controlled by the
upper monitor via communication.
This parameter is used to set the
maximum output frequency of the inverter.
Users need to pay attention to this
parameter because it is the foundation of
the frequency setting and the speed of
acceleration and deceleration.
Setting range: P00.04~400.00Hz
The upper limit of the running frequency is 50.00Hz
-27-
Function parameters
Default Modify
50.00Hz