132 System messages and MMI commands description
Table 17
System messages displayed on the system terminal of TTY (cont'd.)
FXPEC Reset: Power-up/Watchdog/MSL-1 Boot version: xx
Card ID: string
FXNET/FXPEC Main code version: xx {+pROBE}
TSIC Memory Mismatch . . . Rebuild OK
BRSC Local Switch Memory Mismatch, IVDch = x . . . Rebuild OK
Stuck RSIG
R71 CRC. cnt = x
R71 trunc. Cnt = x
R71 misalign. Cnt = x
R71 no resync. Cnt = x
Self-test messages
Card test started...PASSED! or FAILED!
MPU confidence test failed
MPU int mem test failed: address= addr expected= x received = y
Reset caused by the CPU. xx is the boot code version.
Multiple unassisted power-up resets indicate card,
backplane, or supply failure. Watchdog reset may
indicate firmware problem.
Reset caused by the MPU. xx is the boot code version.
Multiple unassisted power-up resets indicate card,
backplane, or supply failure. Watchdog reset may
indicate firmware problem.
Prints the card ID stored in the EEPROM.
This message appears at the end of the boot process.
Hardware or firmware fault (switching mechanism).
Check to see if the Fiber Superloop Network card is
seated correctly in its card slot.
All these messages indicate problem with R71 (RSIG)
signaling. If problem persists, do selftest to identify the
problem, which may be hardware.
In case of selftest failure, the self-test is restarted and
a message is printed to indicate the cause of failure.
If the fault persists, replace the card. The system
will output a message to identify the fault. Failed
component messages and their description are listed
as follows:
The basic confidence test of the MPU of the tested
card failed.
Nortel Communication Server 1000