Nortel 1000 Manual page 134

Fiber remote ipe fundamentals
Table of Contents

Advertisement

134 System messages and MMI commands description
Table 17
System messages displayed on the system terminal of TTY (cont'd.)
A31 failed: cause
Electro-optical packlet testing
Packlet #n equipped! testing...PASSED! or FAILED!
EOI #n failed: cause
EOI #n loopback failed
P/EEPROM failed: pattern/address/program
General card messages
FXNET/FXPEC time: HH:MM dd/mm/yy
Illegal command
Illegal parameter
MMI: string from remote: string
MMI: switched to MSL-1 mode
PLL locked
PLL start bit not ready
PLL locked on prim/sec
The FXPEC TSIC logic failed, where cause identifies
the cause of failure.
The FXPEC TSIC logic failed, where cause identifies
the cause of failure.
If the test result is FAILED!, the additional information
printed on the TTY can be one of the following:
EOI packlet n failed and cause indicates the cause of
the fault.
The loopback test failed on the EOI #n.
EEPROM cannot be reprogrammed. If the test passed,
the card ID is printed.
Time stamp is printed every 15 minutes, where HH:MM
is hour and minute, dd/mm/yy is the day, month, and
year.
Unrecognized command issued by the craftsperson.
Incorrect parameter entry.
String is received from the FXPEC, but FXNET is in
the MMI mode. string represents the actual command
received from the other side.
SUBM R command was executed at the opposite site
to place the MMI terminal in the MSL-1 mode.
FXNET PLL lock was successful.
Problem with PLL. Unplug the card and plug it back in.
In the message reappears, replace the packlet.
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.