Connecting The Fiber-Optic Link To The Remote Ipe Module - Nortel 1000 Manual

Fiber remote ipe fundamentals
Table of Contents

Advertisement

5
Plug the other end of the cable RJ-11 connector into the J6
receptacle on the system monitor in the pedestal.
Refer to
and the Fiber Remote IPE" (page 59)
monitoring cables for a column with the IPE module.
6
Check the NT8D22 System Monitor factory switch settings for
the slave system monitor.
Refer to Option settings, Circuit Card Reference (NN43001-311)
().
7
Plug the NTAK1118 9-pin D-type connector into the 9-pin D-type
connector on the IPE module I/O panel.
8
Plug the other end of the NTAK1118 cable into the terminal or
TTY RS-232 connector.
Connecting the fiber-optic link to the Remote IPE module
The fiber-optic link connects the optical I/O panel connector at the rear of
the Remote IPE module to the optical I/O panel at the rear of the module
housing the NT1P61 Fiber Superloop Network card in the local system.
The routing and splicing of fiber-optic cables along the link should have
been completed before the Fiber Remote IPE site installation.
Each fiber of the fiber-optic cable, at each end of the link, must be
terminated with an FC/PC optical connector. This connector plugs into the
FC/PC optical connector on the I/O panel.
For a single link, connect only two fibers at the end of the cable, one for
the transmit side and one for the receive side. For a redundant link, four
fibers must be connected.
To connect the link to the Remote IPE I/O panel, follow the steps in
Procedure 9 "Connecting the fiber-optic link to the Remote IPE module"
(page
67).
Procedure 9
Connecting the fiber-optic link to the Remote IPE module
Step
Action
1
Identify one link fiber as Tx
or identify four fibers as Tx
redundant link.
2
Identify the transmit and receive connectors on the optical I/O
panel at the rear of the Remote IPE module.
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Floor-standing column Fiber Remote IPE installation 67
Figure 11 "System monitor connections at the local site
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010
for connecting system
--End--
and another as Rx
0
0
, Rx
, Tx
, and Rx
respectively for a
0
0
1
1
for a single link,