3.1 Monitoring Product Life
3.1.3 Preventative Maintenance
• Σ-7S SERVOPACKs with MECHATROLINK-II Communications References or Σ-7S SERVO-
PACKs with MECHATROLINK-III Communications References
Pn514
• Σ-7W SERVOPACKs with MECHATROLINK-III Communications References
Pn514
Pn597
3-4
Parameter

n.
0
Disabled (the above signal output is not used).
(default setting)
Output the signal from the CN1-1 or CN1-2 output ter-

n.
1
minal.
Output the signal from the CN1-23 or CN1-24 output

n.
2
terminal.
Output the signal from the CN1-25 or CN1-26 output

n.
3
terminal.
Parameter

n.
0
Disabled (the above signal output is not used).
(default setting)
Axis A: Output the signal from the CN1-23 or CN1-24
output terminal.

n.
1
Axis B: Output the signal from the CN1-25 or CN1-26
output terminal.
Axis A: Output the signal from the CN1-27 or CN1-28
output terminal.

n.
2
Axis B: Output the signal from the CN1-29 or CN1-30
output terminal.
n.
023
Allocate the signal to CN1-23.
n.
025
Allocate the signal to CN1-25.
n.
027
Allocate the signal to CN1-27.
n.
029
Allocate the signal to CN1-29.
n.
031
Allocate the signal to CN1-31.

n.0
Disabled (the above signal output is not used).
(default setting)

n.1
Output the above signal.

n.2
Invert the above signal and output it.
Description
Description
When
Classifi-
Enabled
cation
After
Setup
restart
When
Classifi-
Enabled
cation
After
Setup
restart
After
Setup
restart