Parameter
n.
003
Allocate the signal to CN1-3.
n.
004
Allocate the signal to CN1-4.
n.
005
Allocate the signal to CN1-5.
n.
006
Allocate the signal to CN1-6.
n.
007
Allocate the signal to CN1-7.
n.
008
Allocate the signal to CN1-8.
n.
009
Allocate the signal to CN1-9.
n.
010
Allocate the signal to CN1-10.
n.
011
Allocate the signal to CN1-11.
Pn597
n.
012
Allocate the signal to CN1-12.
n.
013
Allocate the signal to CN1-13.
n.
014
Allocate the signal to CN1-14.
n.0
Set the signal to always enable drive (always disable forc-
(default set-
ing the motor to stop).
ting)
n.1
Enable drive when the input signal is ON (closed).
n.2
Enable drive when the input signal is OFF (open).
Set the signal to always prohibit drive (always force the
n.3
motor to stop).
1.2.2 Setting the FSTP (Forced Stop Input) Signal
Description
1.2 Forcing the Motor to Stop
When
Classifi-
Enabled
cation
After
Setup
restart
1
1-13