Master Calibration; Input Axis; Destination Country; Measuring Unit Resolution - Magnescale LY71 Instruction And Installation Manual

Counter unit
Hide thumbs Also See for LY71:
Table of Contents

Advertisement

Completing the basic settings
1
After finalizing the measuring unit resolution setting, press the
(Reference: You can complete the basic settings at any time by pressing the
validated setting contents are applied to the settings.)
........
is displayed.
To cancel all setting changes, press the
The settings prior to making the changes are retained.
All clear (factory settings)
When you press the
Press the
Press the
n
When you perform the all clear operation, the advanced setting items also return to the
factory settings. Be sure to write down any necessary contents before performing the all
clear operation. Cleared contents cannot be restored.
2
Press the
key.
........
is displayed.
3
Press the
key.
........ The settings are validated.
The advanced setting items return to the factory settings after making the basic settings.

4-2-1. Master calibration

When using a gauge-type measuring unit, an operation known as master calibration is sometimes performed
when starting operation. The master calibration operation can be simplified if a gauge-type measuring unit
with a reference point is used together with the master calibration function of this counter unit.

4-2-2. Input axis

This determines whether to use only one axis or two axes of the measuring unit. When using two axes, this
also determines whether to perform addition.
When using the comparator, one axis only addition is selected, and the first and second axes cannot be used
independently.

4-2-3. Destination country

This selects the destination country.
STD
Standard (mm display; inch display possible)
US
U.S. (inch display; mm display possible)
JPN
Japan (mm display only)

4-2-4. Measuring unit resolution

Set the resolution of the connected measuring unit.
Counter display A displays the first axis input, and counter display B displays the second axis input. When
the resolution of the connected measuring unit cannot be found within the basic resolutions, press the
key to expand the available resolution options.
LY71
key while
key to clear all the setting contents and return to the factory settings.
key to cancel the all clear operation and return to the original display.
key.
key while
is displayed.
is displayed, the display changes to
key. In this case only
.
4. Settings
4-5
(E)