Installation
Note
Install only fans of the same type. Use the "FAN1" slot for the connecting cable of the fan.
Ensure that the arrow on the device fan points toward the fan bracket. The device fan blows
air into the enclosure.
To install the fan, follow the steps for removing it in reverse order.
See also
Maintenance intervals (Page 82)
7.3.4

Change the fan on drive cage type A

This fan is only installed in the removable tray (drive cage type A) for configurations with
RAID and the hard disk type "Enterprise".
Requirement
● The device is fully disconnected from the line voltage, see section "Switching off the
device (Page 39)".
● The device is open; see section "Open the device. (Page 53)".
● The adapter module for removable drive trays is removed, see section "Installing a 5.25"
adapter module for removable trays (Page 58)".
● An original spare part, i.e. a fan of the same type.
SIMATIC IPC1047
Operating Instructions, 07/2019, A5E45118479-AB
Device maintenance and repair
7.3 Removing and installing hardware
85